Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant

Product Details
Customization: Available
Usage: Orthodontic Material
Usage Times: Non-Disposable
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2006-07-20
Registered Capital
10.35 Million USD
  • Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
  • Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
  • Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
  • Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
  • Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
  • Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Find Similar Products
  • Overview
  • Detailed Photos
  • Company Profile
  • Factory Tour
  • Customer visit
  • Certifications
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Dental Implant
Material
IV Pure Titanium
Applicable Departments
Dental Department
Nature
Implant Materials & Artificial Organs
Certification
CE, FDA
Properties
Implant Materials & Artificial Organs
Type
Implantable Artificial Organs, Submerged Type & in
Instrument Classification
Class III
Diameter
3.4mm/3.8mm/4.3mm/5.0mm
Length
9mm/11mm/13mm/15mm
Feature
Reverse Taper / Straight / Taper Design
Packaging & Delivery
20X30X20 Cm
Single Gross Weight
0.020 Kg
Transport Package
Wooden Box Suitalble for Long-Distance Transporta
Specification
3.4mm. 3.8mm, 4.3mm, 5.0mm, OEM
Trademark
Foosin/, OEM
Origin
Shandong China
HS Code
9021100000

Product Description

CE Titanium Dental Implant Bone Level System Factory Direct Oral Surgical Instrument Teeth Fixture Replace Missing Teeth implant

Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Detailed Photos

 


Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant

Advanced Design Concept&Structure

1) Micro thread and conical shape on the implant above neck part to spread the joint stress out and stimulate jawbone tissue;
2)Cylindrical body to make implanting simpler and get a good primary stability;Deeper biodirectional main thread can generate Bone extrusion and get predictable primary stability.
3) Spiral cutting groof to increase self tapping and provide more space for bone collection and arc bottom.
4) Perfect Connection: Platform switching/Morse Taper/Central Screw connected/Anti-Rotation Cross Keys

Surface Treatment

We use the most advanced surface treatment:S.L.A. It can contact with bone and accelerate osseointegration ,and make a better primary stability.
 
Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Excellent shape
Comparing with cylinder and single thread profile, it has a good primary stability.An obvious superiority can be seen when it used
for low density sclerotin.Meanwhile micro taper and irregular trapezoid thread could spread out the stress from the implant and
the jawbone in order to keep a physiological balance.
It won't be fractured due to the overload of the jawbone and implant fatigue and gives it a less stress so that the jawbone
shrinks and increase bone resorption.
Perfect connection
WEGO Dental Implant System adopted the advanced design of platform switching, Morse's connection and cross key anti-rotation.The
implant and abutment are tightened by central screw. The structure reflects the connection of airtight, power of dispersion and
anti-rotation between the implant and abutment..
Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Surface roughness
Surface roughness:Ra 1.5-2.5 μm,which greatly increases the bonding area between the tissue and the implant surface.
Rapid OsseointegrationBetter Primmary Stability Function
This surface contacts with bone and enhance the osseointegration.The function of bone induction is remarkable.It engourages more
rapid osseointegration on the initial healing stage.WEGO implant system gains a better stability perperty compared with the other
implant models.
Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant



 
 
Perfect connection
WEGO Dental Implant System adopted the advanced design of platform switching, Morse's connection and cross key anti-rotation.The implant and abutment are tightened by central screw. The structure reflects the connection of airtight, power of dispersion and anti-rotation between the implant and abutment.
 
Company Profile

Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Foosin Medical Supplies Inc., Ltd, established in 2005, is a joint venture company between Wego Group and Hong Kong, with total capital over RMB 50 million. We are trying to contribute to make Foosin become to the most powerful manufacture base of surgical needle and surgical sutures in the develop countries. Main product covers Surgical Sutures, Surgical Needles and Dressings.
Factory Tour

Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant

Customer visit

Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
Certifications
Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant
 
Packaging & Shipping
Packing & Shipping
1) Express, sea transportation, air transportation all can be choosed;
2) Items will be shipped within 5 working days or more sooner after balance payment arranged;
3) A tracking No. will be sent to you after your cargo has been loaded;
4) Samples delivery time: 3-5 working days by UPS/ DHL/TNT/ FEDEX, 5-7 working days by EMS;
5) Any shipping details please communicate with sales in advance.
Clinical Trail Dental Implant Animal Experiment Dental Implant Clinical Practice Dental Implant



Q1: Can You Accept OEM Or ODM Orders?
A:Yes, We Can.Customized Orders Are Also Welcomed.


Q2: Where Export Your Products?
A: We export our goods to all markets. Our major markets now are American market and European countries.


Q3: What is Your Delivery Time?
A: Within 20-40 Days After Receiving The Advance Payment(It is According To The Quantity)


Q4: How Do You Control The Items Quality?
A: Company has advanced technical equipment and professional
Talents, adhere to the quality policy "meet and strive to exceed the customer's greatest demand", obtain ISO9000, ISO13485.




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier